MIL-I -21400 (Aer)
Form Factor and Mounting - The equipment shall conform to the requirements
3.4.2
of 3. 2.9 and shall have overall dimensions of 5 -3/4 inches wide by 7-7/8 inches long by 6-1/4 inches
deep behind the panel.
Weight with Mounting - The installed weight of the equipment, with mounting,
3.4.3
shall not exeed 8 pounds.
Input Pulse - The input pulse shall be + 24 to +30 V. D. C. into an input im-
3.4.4
pedance of not less than 2 ohms for a minimum duration of 11 milliseconds. Negative transients of
up to 150 volts and O. 1 120 second pulse duration at the input shall not initiate operation.
Output Pulse - The equipment shall provide output pulses of O.0725 + 0.010
3.4.5
seconds duration.
circuits - With the power switch in the "OFF" position, the equipment shall
3.4.6
be completely shut off and by passed for normal selective release operation.
.
3.4.3 Range
1-600 knots in 1 knot intervals
GROUND SPEED -
150-3200 yards in 25 yard intervals
Spacing
150-3200 feet in 25 foot intervals
1-64 in 1 round intervals
Rounds
- Workmanship, fabrication and manufacturing processes shall
"3. 5
conform to Specification -
MIL-E-54