MIL-A-81378(AS)
6.10.6
Logic-Level Reference - A voltage specified as a logical "O" shall not
exceed +0. S vdc, and a voltage specified as a logical "1" shall be not less than +5 vdc nor
more than the positive supply voltage.
6.10.7
Individual Tests - The following tests shall be performed on each
assembly:
6.10.7.1
Quantity
6 . 1 0 . 7 . 1 . 1 Quantity 2-
(1) S3 to +28 V. D, C. Position
(2) Reset module
- Pin 18 = "1"
(3) Apply 1 fire pulse
- Pin 18 = "l"
(4) Apply 1 fire pulse
- Pin 18 = "0"
(5) Reset module
- Pin 18 = "1"
(6) S3 to Ground Position
6.10.7.1.2 Quantity 3
(1) S4 to +28 VDC Position
(2) Reset Module - Pin 18 "1"
(3) AP PlY 2 fire pulses - Pin 18 = "1"
(4) Apply 1 fire pulse - Pin 18 = "O"
(5) Reset module Pin 18 = "1"
(6) S4 To Ground Position.
6.10.7.1.3 Quantity 4
(1) S5 to +28 VDC Position
(2) Reset module - Pin 18 = "1"
(3) Apply 3 fire pulses - Pin 18 = "1"
(4) Apply 1 fire pulse - Pin 18 = "O"
(6) Reset module Pin 18 = "1"
(6) S5 To Ground Position
6.10.7.1.4 Quantity 5
(1) S6 to +28 VDC Position
(2) Reset module - Pin 18 = "1"
(3) Apply 4 fire pulses - Pin 18 = "1"
15
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business