MIL-A-81373(AS)
(4) Apply l fire puIse - Pin 18 = "O"
(5) Reset module - Pin 18 = "1"
(6) S6 To Ground Position
6.10.7.1.5 Quantity 6
(1) S7 to +28 VDC Position
(2) Reset module - Pin 18 = "1"
(3) Apply 5 fire pulses Pin 18 = "1"
(4) Apply l fire pulse Pin 18 = "O"
(5) Reset module Pin 18 = "1"
(6) S7 To Ground Position
6.10.7.1.6 Quantity 8
(1) S8 to +28 VDC Position
(2) Reset module Pin 18= "1"
(3) Apply 7 fire pulses Pin 18 = "1"
(4) Apply l fire pulse Pin 18= "O"
(5) Reset module Pin 18 = "1"
(6) S8 To Ground Position
Quantity 12
6.10.7.1.7
(1) S9 to +28 VDC Position
(2) Reset module - Pin 18 = "1"
(3) Apply l1 fire pulses - Pin 18 = "1"
(4) Apply- l fire pulse-Pin18 = "O"
(5) Reset module - Pin 18 = "1"
(6) S9 To Ground Position
Quantity 16
6.10.7.1.8
(1) S10 to +28 VDC Position
(2) Reset module - pin 18 = "1"
(3) Apply 15 fire pulses - Pin 18 = "1"
(4) Apply l fire pulse - Pin 18 = "1"
. (5) Reset module-pin18 = "l"
(6) SIO To Ground Position
16